Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Mitchell documents an R11G4113A serial bench path with TI-5036 and the specified additional supply arrangement. Use the current cable sheet to verify the setup. The exact TI-3000JX motor-run configuration remains open.
Sanyo Denki R11G4113A ABSOSYN Serial Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is R11G4113A. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| R11G4113A | Legacy Sanyo motor feedback assembly. Verify exact motor journal and installed connector. | 14-bit serial position and a distinct auxiliary supply. No A/B/Z output per Mitchell. |
| R11ABS | Mitchell test name for a related unidentified encoder. | 13-bit single-turn selection. Confirm the actual encoder label before applying it. |
| E07B151306 | Separate ABSOSYN assembly. | Different resolution and quadrature output. Compare supply and connector details. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Absolute data | 14 bits, 16,384 positions per turn per Mitchell. Mitchell describes a signed turn range around ±4096 turns. |
| Signal path | ABSOSYN serial position. R11G4113A has no quadrature A/B/Z according to Mitchell. |
| Bench supply scope | Mitchell identifies a normal +5 V supply and a separate −5 V path for the R11G4113A fixture. Use the exact approved arrangement. |
| Test lead | TI-5036, 17-pin MS as listed for R11G4113A. |
The table identifies the assembly each value applies to.
Mounting and fit
Use the motor order, date code and installed encoder label to get the shaft and stator drawing. Record mechanical seating and cable exit before disturbing the rotor. On the isolated motor, inspect the center retention and stator lock for movement only where these parts are identified on the applicable drawing.
Interface and measuring method
The receiver reads ABSOSYN serial position and turn information. Use the drive’s serial diagnostics and backup status to trace a fault. A pulse counter cannot establish health on this serial-only unit. Compare any apparent wrap or discontinuity to the configured word format and the intended mechanical travel.
Verified wiring
The TI-5036 fixture and the Sanyo service article identify a separate auxiliary supply path. Have a specialist verify the connector view, referenced floating supply arrangement, serial pair and backup connections against the approved sheet. Use the OEM connector drawing for in-motor wiring and keep the shield and signal return definitions separate.
Cables inside the motor and at the machine
TI-5036 is a 17-pin MS fixture listed for this exact encoder. Compare the device and motor connectors with the current fixture drawing. A circular connector alone cannot establish the supply or serial wiring. Obtain the internal harness and receiver cable number from the OEM motor order.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No response but the normal supply appears present | Have a qualified technician verify the auxiliary supply path under the documented load and check the exact serial wiring. |
| Serial position is valid with a backup alarm | Check the battery and stored-reference procedure for the machine. Preserve the data before reset or disconnect. |
| Counts change unexpectedly at one shaft position | Check profile selection, shaft retention and harness intermittency before changing the motor reference. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use the complete motor nameplate to verify the R11G4113A application. The Mitchell R11ABS run example belongs to a different profile and must be reconciled with the actual fitted motor.
Compare the Sanyo variant that has an independent incremental path. E07B151103 technical guide.
Angle of alignment and commissioning
Record the motor and encoder position reference and capture applicable backup data under the OEM procedure. Check the installed mechanical seating and establish the motor commutation and axis datum using the approved drive routine. Verify each separately after replacement.
Drawings, pin maps and manuals
- Mitchell Sanyo serial encoder guide. R11G4113A data format, bench supply distinction and backup notes.
- Mitchell cable index PDF. TI-5036 exact encoder and 17-pin MS entry.
The references above describe the verified scope. A direct technical PDF for the exact encoder remains to be confirmed.