What specialist testing can show
TI-5000JX bench. Separate resolver signals from the memory-board checks and preserve the original alignment record.
TI-3000JX motor run. Mitchell describes a separate Generic Resolver setup for the supported assembly. Confirm the exact MKE connections and service conditions.
Starting lead. Use the matching resolver and board fixture for the actual connector. Mitchell documents TI-5924 and TI-5040 rev C for the stated setup. Module TI-5104 for the documented board-memory branch.
Bosch Rexroth MKE G / K Resolver and Digital Memory Board technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| MKE G or K | Mitchell’s MKE breakdown maps these codes to its MKD/MKE digital resolver procedure. Verify the full motor and certification marking. |
| G versus K in the linked MKD example | Mitchell describes singleturn G and a K board with a multiturn magnet wheel and battery. Confirm the fitted MKE board before applying that example. |
| MKE N/P | Legacy digital encoder options with separate test hardware. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Resolver branch | AC reference and sine/cosine returns on the documented TI-5924 setup. |
| Memory-board branch | TI-5040 rev C with TI-5104 in Mitchell’s procedure. |
| Run setup | Generic Resolver on the documented TI-3000JX path, subject to fitted motor and service conditions. |
Interface and measuring method
The passive resolver supplies position-related voltages. The board carries identification and alignment data. Isolate winding, harness and board evidence before replacing the assembly.
Mounting and fit
Use the complete MKE frame and OEM documentation. Record the received alignment and original assembly. On a certified motor, refer enclosure opening, cable entry and repairs to service personnel qualified for that exact motor and certification.
Wiring and connector scope
Use the distinct resolver and board diagrams in Mitchell’s MKD/MKE procedure. The board and resolver require different fixture connections. Verify the exact plug before testing and follow the OEM rules for work on the assembly.
Internal motor and machine cables
Match any external cable, connector and cable entry to the MKE motor and its approved installation. Identify the board and resolver leads separately. The TI-5924 and TI-5040 references are for diagnosis in the documented setup.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
A resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.
| Symptom | What to verify |
|---|---|
| Resolver angle follows motion but drive rejects feedback | Check the memory-board identification and original alignment separately. |
| Both sine and cosine low | Verify the approved excitation and the isolated reference path. |
| Turn retention fails on a fitted K board | Confirm the actual board, retention circuit and approved service route. |
Angle of alignment and commissioning
Read and save the incoming memory and measured resolver reference before disturbing the hardware. Mitchell explains that alignment varies across Indramat digital motors. A specialist should verify the actual reference and approved data path.
Motor and drive applications
MKE flameproof motor with documented G or K option
Identify the G or K option and distinguish a winding, harness or memory-board fault within the applicable service scope.
Related SpareFaber guides
Drawings, pin maps and manuals
- Bosch/Rexroth/Indramat MKE Motors. MKE model breakdown, G and K resolver codes
- Indramat/Rexroth MKD/MKE Resolver and Digital Board Test Procedures. Supplementary reference for the stated model or setup.
- Bosch Rexroth MKE project planning manual R911297663. Installation and service requirements for the documented explosion-protected MKE versions.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation