What specialist testing can show
TI-5000JX bench. Read and preserve the received MSK memory and verify the M1 multiturn path.
TI-3000JX motor run. Confirm the complete MSK motor and compatible HIPERFACE run selection.
Starting lead. TI-5093 on the matched MSK motor-side connection. Verify the exact direct lead if needed.
Bosch Rexroth IndraDyn S MSK M1 Multiturn HIPERFACE Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| MSK M1 | Multiturn HIPERFACE. 4,096 distinguishable turns in the cited MSK manual. |
| MSK S1 | Singleturn HIPERFACE with its own position format. |
| MSK M2 | Multiturn EnDat 2.1. The drive and test selection differ. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| M1 analogue tracks | 128 periods per turn in the project manual. |
| M1 absolute field | Multiturn HIPERFACE, with 4,096 turns in the cited configuration. |
| Test connection | TI-5093 and TI-5104 on the documented MSK setup. Match the fitted order and power cable. |
Interface and measuring method
HIPERFACE provides analogue movement signals and a serial channel for position and data. Compare link health, the analogue response and original motor data as independent checks.
Mounting and fit
Use the project and fitted encoder drawings for motor mounting and rear assembly. Verify the shaft seat, restraint and cable route. Preserve the received reference before disturbing the feedback.
Wiring and connector scope
Match the MSK motor-side connector, actual M1 wiring and approved supply. Trace the analogue and serial pairs separately. Use the exact internal encoder drawing for direct bench connection.
Internal motor and machine cables
Identify the motor extension, machine connector and internal loom by full motor and drive orders. TI-5093 is the matched service fixture and has its own wiring documentation.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Serial data valid but movement alarm present | Check the analogue pairs and connector seating separately. |
| Wrong turn count after replacing feedback | Confirm the M1 code, position format and original reference. |
| Motor runs poorly after encoder work | Compare the stored motor data and physical reference before further testing. |
Angle of alignment and commissioning
Capture the original motor memory and reference through the applicable MSK procedure. Confirm the complete motor type and encoder order before programming, aligning or enabling a replacement.
Motor and drive applications
MSK fitted with documented M1 feedback
Compare M1 against S1 singleturn and M2 EnDat, then identify the original memory and fitted encoder.
Related SpareFaber guides
Drawings, pin maps and manuals
- Rexroth MSK support. MSK HIPERFACE motor-side fixture and MSK memory support
- Bosch Rexroth MSK project planning, M1 option in section 4.3. Supplementary reference for the stated model or setup.
- Rexroth Motors. Reference for the fitted feedback or motor option.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.